========================================================================== AST RESEARCH, INC. SOFTWARE BULLETIN # 0102 6-14-96 ========================================================================== TITLE: Server Advanced Diags, Version 2.23 FILENAME(S): 10450316.EXE PART NUMBER(S): 910450-316 SUMMARY File 10450316.EXE contains version 2.23, disk 1 of 1, of the Server Advanced Diagnostics. This update applies to the following systems: 501500, 501502, 501503, 501530, 501723, 501757, 501797, and 501830. This is an update to the Server Advanced Diagnostics. This release is intended to produce a bootable diagnostic diskette. RESOLUTIONS Fixed VGA RAM test failure with Manhattan G. Fixed DMA test failure (hanging) if DPT PCI diskarray is installed. Fixed "invalid resource" error in the Barberpole Printer test. Fixed Wrap Mode test failure in the Mouse test, with Logitech M-S34 mouse. Fixed inaccurate 12-volt reading with the Manhattan P/V due to wrong A/D scaling factor. ENHANCEMENTS Enhanced the DPT SCSI PCI Array controller test to support multiple SCSI channels. The test now can support up to the maximum of three channels available for each DPT PCI SCSI card. Since the test supports up to four DPT PCI cards, maximum of 84 SCSI devices can be tested. PREVIOUS RELEASE(S) N/A NEW FEATURES DPT SCSI Disk Controllers This version of the SCSI Disk tests detects the new PM2022A Caching Disk Controller with the Smart Cache III. ERRATA Parallel Port Internal Loopback test. There is an anomaly with the internal loopback test when it is executed with an external printer attached. Some low cost dot matrix printers may cause this test to fail. In the event that the user experiences an unexpected error with this test, and the printer that is connected is known to be otherwise functioning correctly, disconnect the printer and retry the test. NOTES Platform compatibility: This program is backward compatible with version 2.22. This program is intended to be run on Manhattan server systems only. When attempting to run this program on a Manhattan SMP, an error will be displayed indicating the user is running the incorrect program. To test SMP systems, use Server Advanced Diagnostics with part number 910595-035. File SMP3.EXE is available for download from AST's On-Line! services. For additional information, see Software Bulletin # 0131 (0131SB.TXT) on AST's On-Line! services. When attempting to run this program on a Manhattan S/6200 and a Manhattan Commerce Pro, an error will be displayed indicating the user is running the incorrect program. To test Manhattan S/6200 and a Manhattan Commerce Pro systems, use Advanced Diagnostics with part number 912796-032. This file ships with the system and is not available for download from AST's on-line services. For information on installing this update, please view the README.TXT file that accompanies the update. You can download this file from the following services: AST WWW Site: http://www.ast.com AST Americas On-Line! BBS*: See IB0001.TXT CompuServe: GO: ASTFORUM * Refer to IB0001.TXT for a list of AST's international BBS numbers. TAN N/A --------------------------------------------------------------------- The information in this data sheet is subject to change without notice. AST Research, Inc. shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This material contains information protected by copyright. No part of this material may be reproduced in any form without prior written consent from AST Research, Inc. All rights reserved. ---------------------------------------------------------------------