= AST RESEAARCH, INC. TECHNICAL BULLETIN # 1032 12-8-94 = FLOPPY ERRORS ON BRAVO LC WITH ATI MACH64 VLB VIDEO ADAPTER PROBLEM: After installing an ATI Mach64 VLB Pro Turbo video adapter board in the AST Bravo LC system, the system reports read and write error messages accessing the floppy drive. CAUSE: The address line buffers on the Mach64 (and Mach32) VLB video adapters cause the lines to float, also causing the source and destination addresses of a DMA transfer to change unexpectedly. The ATI board (part number 109-26900-20) may be failing. Locate the ATI part number on the upper right corner of the component side of the board. SYSTEMS AFFECTED: AST PART NUMBER DESCRIPTION 501378-XXX BRAVO LC 486/33S 501379-XXX BRAVO LC 486/33 501380-XXX BRAVO LC486/66D 501381-XXX BRAVO LC486/100t 501433-XXX BRAVO LC486/50S 501437-XXX BRAVO LC486DX4-100MPC 501444-XXX BRAVO LC486DX4-100MPC SOLUTION: Contact ATI at (905) 882-2600 and request a Return Material Authorization (RMA) number for the ATI video board (part number 109-26900-30 or later). This version of the video board will work properly.