= AST RESEARCH, INC. TECHNICAL BULLETIN # 1193 5-24-95 = DESKTOP SYSTEMS HANG OPENING AND CLOSING APPLICATIONS IN WINDOWS PROBLEM Various desktop systems may hang when attempting to open or close applications in Windows. The system may return error messages such as the following: Excel causes a General Protection Fault in module VGA.DRV at 0009:0D26. or EMM 386 has detected error # 06 in an application at memory address 00B8:0BC9. CAUSE There is an impedance mismatch (using certain vendors' parts) in the memory address lines to the SIMMS. SYSTEMS AFFECTED AST PART NUMBER AND DESCRIPTION 501611-XXX BRAVO MS 4-50S 501612-XXX BRAVO MS 4-66D 501440-XXX BRAVO MS 4-33S 501432-XXX PREMMIA MX 4-100 501429-XXX PREMMIA MX 4-66D 501655-XXX BRAVO MS-L 4-50D 501644-XXX ADVANTAGE! CMT 2-66D 501443-XXX BRAVO MS-L 4-100T SOLUTION Return the system to an AST Authorized Service Center for system board replacement. Replace the system board with the corresponding AST part number: AST PART NUMBER 202612-XXX 202637-XXX 202694-XXX 202695-XXX 202705-XXX For specific revision levels, contact your AST Authorized Service Center. NOTE To find out if the system has the above problem, inspect the system board at locations U11, U12, and U13. If the board has an IC (integrated circuit) part number 74F245 from Texas Instruments or Signetics, the board should be replaced. See part numbers above. CAUTION This modification should be performed ONLY by a qualified service technician. It is strongly recommended that this replacement be completed by an AST Authorized Service Center. In no case will AST Research, Inc. be liable for damage to the system and its components, or loss of data caused by improper modification. PREREQUISITES A full backup of all data on the hard drive in the computer is strongly suggested. TIME REQUIRED 30 minutes. STATUS VERIFICATION The revision level of the AST system board can be identified by observing the revision letter at the end of the nine-digit part number located on the solder side of the system board. TOOLS REQUIRED: Standard computer tools. INSTALLATION PROCEDURE Refer to the system Hardware Maintenance Manual. Removal and replacement of system "Field Replaceable Units" (FRUs) should only be performed according to the installation procedures approved and prescribed by AST Research, Inc. Remove the system board according to procedures approved and prescribed by AST Research, Inc. CHECK-OUT PROCEDURE To verify proper operation of the system upon completion of this replacement, follow the setup and test procedures described in the AST User's Manual. NOTE Warranty reimbursement for this replacement requires prior AST Research, Inc. approval. The warranty on this system will become VOID if this replacement is completed by ANYONE other than an AST Authorized Service Center.