= AST RESEARCH, INC. TECHNICAL BULLETIN # 1204 6-6-95 = AST DESKTOPS NOT RECOGNIZING ADD-ON BOARDS PROBLEM AST desktop systems may fail to recognize the modem, the ISA adapter, or other add-on boards. CAUSE The capacitor connected to the signal line 'RSTDRV'inhibits proper transfer of the ISA reset signal. SYSTEMS AFFECTED AST PART NUMBER AND DESCRIPTION 501533-XXX BRAVO P-60 501534-XXX BRAVO P-90 501535-XXX BRAVO MS FAL 501543-XXX ADVANTAGE! RMS P/60 501544-XXX ADVANTAGE! RMS P/90 501545-XXX ADVANTAGE! RMT P/60 501546-XXX ADVANTAGE! RMT P/90 501613-XXX BRAVO MS P-90 501650-XXX BRAVO MS-L P/60 501651-XXX BRAVO MS-L P/90 501659-XXX BRAVO MS-T P/60 501660-XXX BRAVO MS-T P/90 501679-XXX BRAVO MS P-60 501680-XXX BRAVO MS P-90 510695-XXX ADVANTAGE! 6075P 501696-XXX ADVANTAGE! 8075P 501697-XXX ADVANTAGE! 8090P 501699-XXX PREMMIA MX P/75 501701-XXX BRAVO MS P-75 501702-XXX BRAVO MS-L P/75 501703-XXX BRAVO MS-T P/75 501754-XXX BRAVO MS P/100 501765-XXX BRAVO MS P-75 501710-XXX BRAVO LC P/75 501713-XXX ADVANTAGE! 6060P SOLUTION The RSTDRV capacitor has been removed from the new version of the riser card. The solution is to replace the riser card. See part numbers and revision levels below. CAUTION This modification should be performed ONLY by a qualified service technician. It is strongly recommended that this change be completed by an AST Authorized Service Center. In no case will AST Research, Inc. be liable for damage to the system and its components, or loss of data caused by improper modification. PREREQUISITES A full backup of all data on the hard drive in the computer is strongly suggested. TIME REQUIRED 30 minutes. STATUS VERIFICATION The revision level of the AST riser card can be identified by observing the revision letter at the end of the nine-digit part number located on the solder side of the card. PARTS REQUIRED AST PART NUMBER DESCRIPTION REVISION 202719-001 PCBA RISER CARD LOW PROFILE B 202720-001 PCBA RISER CARD MID SIZE X04 or higher 202721-001 *PCBA RISER CARD FULL SIZE X02 or higher 202721-002 PCBA RISER CARD FULL SIZE X02 or higher 202722-001 PCBA RISER CARD MINI TOWER X04 or higher *502141405HH (HK) 502091718MH (FW) TOOLS REQUIRED Standard computer tools. INSTALLATION PROCEDURE Refer to the system Hardware Maintenance Manual. Removal and replacement of system "Field Replaceable Units" (FRUs) should only be performed according to the installation procedures approved and prescribed by AST Research, Inc. Remove the riser card according to procedures approved and prescribed by AST Research, Inc. CHECK-OUT PROCEDURE To verify proper operation of the system upon completion of this change, follow the setup and test procedures described in the AST User's Manual. NOTE Warranty reimbursement for this change requires prior AST Research, Inc. approval. The warranty on this system will become VOID if this change is completed by ANYONE other than an AST Authorized Service Center.