Last Revised AST RESEARCH, INC. TECHNICAL BULLETIN # 1748 09/02/97 TITLE: Ascentia A Plus and Minidock ISSUE After docking the Ascentia A Plus to the minidock under Windows 95, the PC card slots in the minidock may not function properly. This issue affects the following Ascentia A Plus systems: 503375-xxx, 503377-xxx. BACKGROUND N/A ACTION Use the Hard Drive Restore CD that shipped with the Ascentia A Plus system to restore the operating system and applications. It is not necessary to format the partition on the system. To perform the restoration, follow the steps below: 1. Enter CMOS Setup by pressing the [F2] key at boot. 2. Use the arrow keys to select the Boot option on the menu and press the [Enter] key, 3. Use the arrow keys to select "CD-ROM drive". Then press the space key until this option is at the top. 4. Insert the AST Restore CD in the CD-ROM Drive, save the changes, and exit CMOS Setup. The system will boot to the CD and present two options: The first option will format the hard drive and restore the Windows 95 operating system and drivers. This option will result in a loss of all data currently on the drive. The second option will restore the Windows 95 operating system and all pre-installed applications without formatting the hard drive. This option will not result in loss of any data on the hard drive but any third party applications will need to be re-installed. Before docking the system, remove any PC cards from the computer and the minidock. Shut the system down, dock with the minidock, and turn the system ON. Windows 95 will detect the minidock and setup a new hardware profile. After this process is complete, reboot the system, open the Control Panel, and double-click the PC card icon. This will launch the PC Card Hardware Wizard. Follow the directions on the screen. After the wizard is complete, cold boot the system to complete the operation. NOTES AST is not responsible for any data lost as result of this operation. TAN TPR 3937AC --------------------------------------------------------------------- The information in this data sheet is subject to change without notice. AST Research, Inc. shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. This material contains information protected by copyright. No part of this material may be reproduced in any form without prior written consent from AST Research, Inc. All rights reserved. --------------------------------------------------------------------- Template Rev 02