============================================================================= AST RESEARCH, INC. FIELD CHANGE NOTICE #0071 07-15-92 ============================================================================= BRAVO 486-25 AND BOUNDS CHECKER SOFTWARE PURPOSE: To allow proper operation of the application "Bounds Checker" from Nu-Mega Technologies, Inc. When the driver BC.SYS is loaded via the CONFIG.SYS file, the system will not "warm boot" using the CTL-ALT-DEL key sequence. CAUTION: This modification should be performed by a qualified service technician. It is strongly recommended that this FCN be completed by an AST Authorized Service Center. In no case will AST Research, Inc. be liable for damage to the system and its components or loss of data caused by improper modification. PREREQUISITES: None TIME REQUIRED: 30 Minutes ASSEMBLIES AFFECTED: This FCN should be installed in the Bravo 486-25 if the keyboard controller is at the revision level described in the table below: AST REVISION PART NUMBER DESCRIPTION LEVEL 237002-001 Keyboard 1.01 or Controller below STATUS VERIFICATION: The revision level of the keyboard controller can be identified by 1) Observing the revision letter at the end of the nine digit part number located on the label of the keyboard controller, which is at position U70 on the system board. 2) Observing the revision level returned by the "SYSTEM CONFIGURATION" option of the AST Advanced Diagnostics program (AST part number 500881-001). PARTS REQUIRED: The proper revision of the keyboard controller is available either as a separate item or as part of the BIOS upgrade kit listed below: AST REVISION PART NUMBER DESCRIPTION LEVEL 237002-002 Keyboard 1.02 or controller above 500890-003 BIOS Upgrade 1.22 E or above TOOLS REQUIRED: Standard computer tools DIAGNOSTICS REQUIRED: None INSTALLATION PROCEDURE: Removal and replacement of system "Field Replaceable Units" (F.R.U.s) should only be performed according to the installation procedures approved and prescribed by AST Research, Inc. CHECK-OUT PROCEDURE: To verify proper operation of the system upon completion of this FCN, follow the setup and test procedures described in the AST User's Manual. NOTE: Warranty reimbursement for installation of this FCN requires prior approval of AST Research, Inc.