-- AT-QOS.MIB, Allied Telesis enterprise MIB: Quality Of Service module
--
-- Copied from ATR-QOS.MIB of pre 2.9.1 release
--
-- Copyright (c) 2006 by Allied Telesis, Inc.
-- All rights reserved.
-- 
-- ============================================================================

AT-QOS-MIB DEFINITIONS ::= BEGIN

IMPORTS
    MODULE-IDENTITY,
    OBJECT-TYPE,
    Counter32,
    Counter64,
    Integer32,
    Gauge32
        FROM SNMPv2-SMI

    DisplayString
        FROM SNMPv2-TC

	modules
		FROM AT-SMI-MIB
;

qos MODULE-IDENTITY
    LAST-UPDATED "200412011525Z"
    ORGANIZATION "Allied Telesis, Inc"
	CONTACT-INFO
	    "http://www.alliedtelesis.com"
	DESCRIPTION
	    "This MIB file contains definitions of managed objects for the
	    handling QoS on Allied Telesis switches. There are a
                number of tables designed to be generic to
	    all ATR switches supporting QoS in silicon, and well as tables for
	    specific AT switches or switch familes."

    REVISION "200412011525Z"
DESCRIPTION
	"Initial Revision"

::= { modules 99 }

-- ============================================================================
-- ============================================================================
-- QoS Switch group
-- ============================================================================
-- ============================================================================

qosSwitch OBJECT IDENTIFIER ::= { qos 1 }

-- =================================================
-- QoS Switch Port table
-- =================================================

qosSwitchPortTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF QosSwitchPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Generic port configuration for QoS, indexed by port index."
    ::= { qosSwitch 1 }

qosSwitchPortEntry OBJECT-TYPE
    SYNTAX      QosSwitchPortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A single switch port entry for QoS."
    INDEX   { qosSwitchPortIndex }
    ::= { qosSwitchPortTable 1 }

QosSwitchPortEntry ::=
    SEQUENCE {
        qosSwitchPortIndex
            Integer32,
        qosSwitchPortPolicyIndex
            Integer32
    }

qosSwitchPortIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Port index of the port entry. This index is the same port number
        used in CLI commands, and the same index as appears in other MIB
        tables related to switch ports."
    ::= { qosSwitchPortEntry 1 }

qosSwitchPortPolicyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..256)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Policy index of the policy for this port. Policy index numbers for
        CLI commands start at 0, while SNMP indexes must start at 1. This
        means that the policy index in this MIB variable is 1 more than the
        index for the same policy as entered for CLI commands."
    ::= { qosSwitchPortEntry 2 }

-- ============================================================================
-- Policy table
-- ============================================================================

qosSwitchPolicyTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF QosSwitchPolicyEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "QoS policy configuration, indexed by policy index."
    ::= { qosSwitch 2 }

qosSwitchPolicyEntry OBJECT-TYPE
    SYNTAX      QosSwitchPolicyEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A policy entry containing configuration information for
         a single policy."
    INDEX       { qosSwitchPolicyIndex }
    ::= { qosSwitchPolicyTable 1 }

QosSwitchPolicyEntry ::=
    SEQUENCE {
        qosSwitchPolicyIndex
            Integer32,
        qosSwitchPolicyDescription
            OCTET STRING,
        qosSwitchPolicyDefaultTCDropBWClass3
            INTEGER,
        qosSwitchPolicyDefaultTCIgnoreBWClass
            INTEGER,
        qosSwitchPolicyDefaultTCMarkValue
            Integer32,
        qosSwitchPolicyDefaultTCMaxBandwidth
            Integer32,
        qosSwitchPolicyDefaultTCMaxBurstSize
            Integer32,
        qosSwitchPolicyDefaultTCMinBandwidth
            Integer32,
        qosSwitchPolicyDefaultTCMinBurstSize
            Integer32,
        qosSwitchPolicyDefaultTCPremarking
            INTEGER,
        qosSwitchPolicyDefaultTCRemarking
            INTEGER
    }

qosSwitchPolicyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..256)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index of this policy entry. Policy index numbers for
        CLI commands start at 0, while SNMP indexes must start at 1. This
        means that the policy index in this MIB variable is 1 more than the
        index for the same policy as entered for CLI commands."
    ::= { qosSwitchPolicyEntry 1 }

qosSwitchPolicyDescription OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE (0..15))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An optional description for the policy, as entered via the CLI."
    ::= { qosSwitchPolicyEntry 2 }

qosSwitchPolicyDefaultTCDropBWClass3 OBJECT-TYPE
    SYNTAX      INTEGER {
                    no(0),
                    yes(1)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies whether traffic that exceeds the bandwidth for the
        default traffic class be dropped or not. The bandwidth limit is the
        combined total of the variables qosSwitchPolicyDefaultTCMaxBandwidth
        and qosSwitchPolicyDefaultTCMaxBurstSize. A value of yes(1) indicates
        that traffic exceeding the bandwidth limit is dropped immediately. A
        value of no(0) indicates that the excess traffic is marked as
        bandwidth class 3 and is therefore eligible for dropping by the RED
        curve settings."
    ::= { qosSwitchPolicyEntry 3 }

qosSwitchPolicyDefaultTCIgnoreBWClass OBJECT-TYPE
    SYNTAX      INTEGER {
                    no(0),
                    yes(1)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies whether the traffic metering stage acknowledges any
        bandwidth class assigned to flows processed by the default traffic
        class. If set to yes(1), previously assigned bandwidth classes will
        be ignored will be ignored and the bandwidth class of the traffic
        will be set according to the meter conformance level of the flow."
    ::= { qosSwitchPolicyEntry 4 }

qosSwitchPolicyDefaultTCMarkValue OBJECT-TYPE
    SYNTAX      Integer32 (0..63 | 256)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "When the qosSwitchPolicyDefaultTCPremarking variable is set to
        usemarkvalue(1), this variable specifies the index into the DSCP
        MAP table to use for remarking. A value in the range 0 to 63
        indicates the DSCP to use, the value 256 indicates that no DSCP
        value has been defined for the default traffic class for this policy."
    ::= { qosSwitchPolicyEntry 5 }

qosSwitchPolicyDefaultTCMaxBandwidth OBJECT-TYPE
    SYNTAX      Integer32 (0..16000000 | 2147483647)
	UNITS		"kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the maximum bandwidth available to the default traffic
        class. Traffic under this bandwidth will be designated as bandwidth
        class 2. The value 2147483647 indicates that there is no limit on
        the maximum bandwidth for the default traffic class for this
        policy."
    ::= { qosSwitchPolicyEntry 6 }

qosSwitchPolicyDefaultTCMaxBurstSize OBJECT-TYPE
    SYNTAX      Integer32 (0..16000000)
	UNITS		"kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the maximum bandwidth above the bandwidth specified by
        qosSwitchPolicyDefaultTCMaxBandwidth before traffic is marked as
        bandwidth class 3."
    ::= { qosSwitchPolicyEntry 7 }

qosSwitchPolicyDefaultTCMinBandwidth OBJECT-TYPE
    SYNTAX      Integer32 (0..16000000 | 2147483647)
	UNITS		"kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the minimum bandwidth reserved for the default traffic
        class. Traffic under this bandwidth will be marked as bandwidth
        class 1. The value 2147483647 indicates that there is no limit on
        the minimum bandwidth for the default traffic class for this
        policy."
    ::= { qosSwitchPolicyEntry 8 }

qosSwitchPolicyDefaultTCMinBurstSize OBJECT-TYPE
    SYNTAX      Integer32 (0..16000000)
	UNITS		"kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the maximum amount of data above the bandwidth specified
        in the variable qosSwitchPolicyDefaultTCMinBandwidth before traffic
        is marked as bandwidth class 2."
    ::= { qosSwitchPolicyEntry 9 }

qosSwitchPolicyDefaultTCPremarking OBJECT-TYPE
    SYNTAX      INTEGER {
                    none(0),
                    usemarkvalue(1),
                    usedscp(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the QoS action to take on traffic in the default traffic
        class before metering actions are taken. If none(0) is specified,
        the traffic is passed to the metering stage. If usemarkvalue(1) is
        specified, the QoS settings are taken from the variable
        qosSwitchPolicyDefaultTCMarkValue used as an index into the DCSP
        MAP table. If usedscp(2) is specified, the DSCP value in the data
        frames is used as an index into the DSCP MAP table."
    ::= { qosSwitchPolicyEntry 10 }

qosSwitchPolicyDefaultTCRemarking OBJECT-TYPE
    SYNTAX      INTEGER {
                    none(0),
                    usedscpmap(1),
                    bwclass(2),
                    priority(3),
                    bwclasspriority(4)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the action to take after the metering stage for traffic
        in the default traffic class. The metering stage assigns a
        temporary value of bandwidth class to the flow which is used to
        determine its per-hop behaviour. If this variable is set to
        bwclass(2) or bwclasspriority(4), the temporary bandwidth class
        becomes the new bandwidth class for the flow. If priority(3) or
        bwclasspriority(4) is specified, the currently
        assigned queue for frames in this traffic class is used in
        conjunction with the temporary bandwidth class to determine the new
        value of the VLAN Tag User Priority field. If usedscpmap(1) is
        specified, the temporary value is used (in conjunction with the
        DSCP of the frame) as an index into the DSCP MAP table, which then
        assigns the actual, new values for bandwidth class, DSCP, Egress
        Queue and VLAN Tag User Priority. A value of none(0) for this
        variable means that no remarking of the packet is done after the
		metering stage."
    ::= { qosSwitchPolicyEntry 11 }

-- ============================================================================
-- Traffic Class table
-- ============================================================================

qosSwitchTrafficClassTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF QosSwitchTrafficClassEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Traffic class configuration, indexed by traffic class index."
    ::= { qosSwitch 3 }

qosSwitchTrafficClassEntry OBJECT-TYPE
    SYNTAX      QosSwitchTrafficClassEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A traffic class entry containing configuration information for
        a single traffic class."
    INDEX   { qosSwitchTrafficClassIndex }
    ::= { qosSwitchTrafficClassTable 1 }

QosSwitchTrafficClassEntry ::=
    SEQUENCE {
        qosSwitchTrafficClassIndex
            Integer32,
    qosSwitchTrafficClassPolicyNumber
	Integer32,
        qosSwitchTrafficClassDescription
            OCTET STRING,
        qosSwitchTrafficClassDropBWClass3
            INTEGER,
        qosSwitchTrafficClassIgnoreBWClass
            INTEGER,
        qosSwitchTrafficClassMarkValue
            Integer32,
        qosSwitchTrafficClassMaxBandwidth
            Integer32,
        qosSwitchTrafficClassMaxBurstSize
            Integer32,
        qosSwitchTrafficClassMinBandwidth
            Integer32,
        qosSwitchTrafficClassMinBurstSize
            Integer32,
        qosSwitchTrafficClassPremarking
            INTEGER,
        qosSwitchTrafficClassRemarking
            INTEGER
    }

qosSwitchTrafficClassIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..1024)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index of this traffic class entry. Traffic class index numbers
        for CLI commands start at 0, while SNMP indexes must start at 1. 
        This means that the traffic class index in this MIB variable is 1
        more than the index for the same traffic class as entered for CLI
        commands."
    ::= { qosSwitchTrafficClassEntry 1 }

qosSwitchTrafficClassPolicyNumber OBJECT-TYPE
    SYNTAX      Integer32 (0..256)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Policy index of the policy to which this traffic class belongs.
        Policy index numbers for CLI commands start at 0, while SNMP
        indexes must start at 1. This means that the policy index in this
        MIB variable is 1 more than the index for the same policy as
        entered for CLI commands. A value of 0 for this variable means
        that the traffic class has not been added to a policy yet."
    ::= { qosSwitchTrafficClassEntry 2 }

qosSwitchTrafficClassDescription OBJECT-TYPE
    SYNTAX      OCTET STRING (SIZE (0..15))
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "An optional description for this traffic class."
    ::= { qosSwitchTrafficClassEntry 3 }

qosSwitchTrafficClassDropBWClass3 OBJECT-TYPE
    SYNTAX      INTEGER {
                    no(0),
                    yes(1)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies whether traffic that exceeds the bandwidth for
        this traffic class be dropped or not. The bandwidth limit is the
        combined total of the variables qosSwitchTrafficClassMaxBandwidth
        and qosSwitchTrafficClassMaxBurstSize A value of yes(1) indicates
        that traffic exceeding the bandwidth limit is dropped immediately. A
        value of no(0) indicates that the excess traffic is marked as
        bandwidth class 3 and is therefore eligible for dropping by the RED
        curve settings."
    ::= { qosSwitchTrafficClassEntry 4 }

qosSwitchTrafficClassIgnoreBWClass OBJECT-TYPE
    SYNTAX      INTEGER {
                    no(0),
                    yes(1)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies whether the traffic metering stage acknowledges any
        bandwidth class assigned to flows processed by this traffic
        class. If set to yes(1), previously assigned bandwidth classes will
        be ignored will be ignored and the bandwidth class of the traffic
        will be set according to the meter conformance level of the flow."
    ::= { qosSwitchTrafficClassEntry 5 }

qosSwitchTrafficClassMarkValue OBJECT-TYPE
    SYNTAX      Integer32 (0..63 | 256)
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "When the qosSwitchTrafficClassPremarking variable is set to
        usemarkvalue(1), this variable specifies the index into the DSCP
        MAP table to use for remarking. A value in the range 0 to 63
        indicates the DSCP to use, the value 256 indicates that no DSCP
        value has been defined for this traffic class."
    ::= { qosSwitchTrafficClassEntry 6 }

qosSwitchTrafficClassMaxBandwidth OBJECT-TYPE
    SYNTAX      Integer32 (0..16000000 | 2147483647)
	UNITS		"kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the maximum bandwidth available to this traffic
        class. Traffic under this bandwidth will be designated as bandwidth
        class 2. The value 2147483647 indicates that there is no limit on
        the maximum bandwidth for this traffic class."
    ::= { qosSwitchTrafficClassEntry 7 }

qosSwitchTrafficClassMaxBurstSize OBJECT-TYPE
    SYNTAX      Integer32 (0..16000000)
	UNITS		"kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the maximum bandwidth above the bandwidth specified by
        qosSwitchTrafficClassMaxBandwidth before traffic is marked as
        bandwidth class 3."
    ::= { qosSwitchTrafficClassEntry 8 }

qosSwitchTrafficClassMinBandwidth OBJECT-TYPE
    SYNTAX      Integer32 (0..16000000 | 2147483647)
	UNITS		"kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the minimum bandwidth reserved for this traffic
        class. Traffic under this bandwidth will be marked as bandwidth
        class 1. The value 2147483647 indicates that there is no limit on
        the minimum bandwidth for this traffic class."
    ::= { qosSwitchTrafficClassEntry 9 }

qosSwitchTrafficClassMinBurstSize OBJECT-TYPE
    SYNTAX      Integer32 (0..16000000)
	UNITS		"kbps"
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the maximum amount of data above the bandwidth specified
        in the variable qosSwitchTrafficClassMinBandwidth before traffic
        is marked as bandwidth class 2."
    ::= { qosSwitchTrafficClassEntry 10 }

qosSwitchTrafficClassPremarking OBJECT-TYPE
    SYNTAX      INTEGER {
                    none(0),
                    usemarkvalue(1),
                    usedscp(2)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the QoS action to take on traffic in this traffic
        class before metering actions are taken. If none(0) is specified,
        the traffic is passed to the metering stage. If usemarkvalue(1) is
        specified, the QoS settings are taken from the variable
        qosSwitchTrafficClassMarkValue used as an index into the DCSP
        MAP table. If usedscp(2) is specified, the DSCP value in the data
        frames is used as an index into the DSCP MAP table."
    ::= { qosSwitchTrafficClassEntry 11 }

qosSwitchTrafficClassRemarking OBJECT-TYPE
    SYNTAX      INTEGER {
                    none(0),
                    usedscpmap(1),
                    bwclass(2),
                    priority(3),
                    bwclasspriority(4)
                }
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "Specifies the action to take after the metering stage for traffic
        in this traffic class. The metering stage assigns a
        temporary value of bandwidth class to the flow which is used to
        determine its per-hop behaviour. If this variable is set to
        bwclass(2) or bwclasspriority(3), the temporary bandwidth class
        becomes the new bandwidth class for the flow. If priority(3) or
        bwclasspriority(4) is specified, the currently
        assigned queue for frames in this traffic class is used in
        conjunction with the temporary bandwidth class to determine the new
        value of the VLAN Tag User Priority field. If usedscpmap(1) is
        specified, the temporary value is used (in conjunction with the
        DSCP of the frame) as an index into the DSCP MAP table, which then
        assigns the actual, new values for bandwidth class, DSCP, Egress
        Queue and VLAN Tag User Priority. A value of none(0) for this
        variable means that no remarking of the packet is done after the
		metering stage."
    ::= { qosSwitchTrafficClassEntry 12 }

-- ============================================================================
-- ============================================================================
-- 8948 specific stuff. The tables in this section are specific to the 8948
-- switch, because they relate directly to the hardware used in this switch.
-- Other switches that use the same hardware will also support this MIB table.
-- ============================================================================
-- ============================================================================

qosSwitch8948 OBJECT IDENTIFIER ::= { qosSwitch 4 }

-- ============================================================================
-- 8948 port table - 8948 specific extensions to the qosSwitchPortTable
-- ============================================================================

qosSwitch8948PortTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF QosSwitch8948PortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Port configuration, indexed by port index."
    ::= { qosSwitch8948 1 }

qosSwitch8948PortEntry OBJECT-TYPE
    SYNTAX      QosSwitch8948PortEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A single switch port entry."
    AUGMENTS    { qosSwitchPortEntry }
    ::= { qosSwitch8948PortTable 1 }

QosSwitch8948PortEntry ::=
    SEQUENCE {
        qosSwitch8948PortDefaultTCCountersAggregateBytes
            Counter64,
        qosSwitch8948PortDefaultTCCountersBwConformanceClass1Bytes
            Counter64,
        qosSwitch8948PortDefaultTCCountersBwConformanceClass2Bytes
            Counter64,
        qosSwitch8948PortDefaultTCCountersBwConformanceClass3Bytes
            Counter64,
        qosSwitch8948PortDefaultTCCountersDroppedBytes
            Counter64,
        qosSwitch8948PortQueueLength
		    Gauge32,
        qosSwitch8948PortQueue0Length
		    Gauge32,
        qosSwitch8948PortQueue1Length
		    Gauge32,
        qosSwitch8948PortQueue2Length
		    Gauge32,
        qosSwitch8948PortQueue3Length
		    Gauge32,
        qosSwitch8948PortQueue4Length
		    Gauge32,
        qosSwitch8948PortQueue5Length
		    Gauge32,
        qosSwitch8948PortQueue6Length
		    Gauge32,
        qosSwitch8948PortQueue7Length
		    Gauge32
    }

qosSwitch8948PortDefaultTCCountersAggregateBytes OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total number of bytes classified by the default traffic class
        on this port."
    ::= { qosSwitch8948PortEntry 1 }

qosSwitch8948PortDefaultTCCountersBwConformanceClass1Bytes OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes classified by the default traffic class on
        this port conforming to bandwidth class 1."
    ::= { qosSwitch8948PortEntry 2 }

qosSwitch8948PortDefaultTCCountersBwConformanceClass2Bytes OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes classified by the default traffic class on
        this port conforming to bandwidth class 2."
    ::= { qosSwitch8948PortEntry 3 }

qosSwitch8948PortDefaultTCCountersBwConformanceClass3Bytes OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes classified by the default traffic class on
        this port conforming to bandwidth class 3."
    ::= { qosSwitch8948PortEntry 4 }

qosSwitch8948PortDefaultTCCountersDroppedBytes OBJECT-TYPE
    SYNTAX      Counter64
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes dropped by the default traffic class on
        this port."
    ::= { qosSwitch8948PortEntry 5 }

qosSwitch8948PortQueueLength OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total number of packets currently queued for transmission on
        this port."
    ::= { qosSwitch8948PortEntry 6 }

qosSwitch8948PortQueue0Length OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets currently queued for transmission on this
        port in queue 0.
        The numbering of queues indicates the priority of handling the
        traffic in that queue, with the higher queue number getting
        higher priority. The priority values in packets are mapped to
        queues via a priority to queue mapping. The default priority to
        queue mapping is as follows:
        Priority	Queue
        value       number
        7           7
        6           6
        5           5
        4           4
        3           3
        2           1
        1           0
        0           2
        This mapping allows the default priority value of 0 to map to a
        queue which is not the lowest priority queue, allowing traffic
        classes to be assigned a lower priority queue than the default."
    ::= { qosSwitch8948PortEntry 7 }

qosSwitch8948PortQueue1Length OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets currently queued for transmission on this
        port in queue 1. See the description for qosSwitch8948PortQueue0Length
        to understand the meaning of queue numbers."
    ::= { qosSwitch8948PortEntry 8 }

qosSwitch8948PortQueue2Length OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets currently queued for transmission on this
        port in queue 2. See the description for qosSwitch8948PortQueue0Length
        to understand the meaning of queue numbers."
    ::= { qosSwitch8948PortEntry 9 }

qosSwitch8948PortQueue3Length OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets currently queued for transmission on this
        port in queue 3. See the description for qosSwitch8948PortQueue0Length
        to understand the meaning of queue numbers."
    ::= { qosSwitch8948PortEntry 10 }

qosSwitch8948PortQueue4Length OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets currently queued for transmission on this
        port in queue 4. See the description for qosSwitch8948PortQueue0Length
        to understand the meaning of queue numbers."
    ::= { qosSwitch8948PortEntry 11 }

qosSwitch8948PortQueue5Length OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets currently queued for transmission on this
        port in queue 5. See the description for qosSwitch8948PortQueue0Length
        to understand the meaning of queue numbers."
    ::= { qosSwitch8948PortEntry 12 }

qosSwitch8948PortQueue6Length OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets currently queued for transmission on this
        port in queue 6. See the description for qosSwitch8948PortQueue0Length
        to understand the meaning of queue numbers."
    ::= { qosSwitch8948PortEntry 13 }

qosSwitch8948PortQueue7Length OBJECT-TYPE
    SYNTAX      Gauge32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of packets currently queued for transmission on this
        port in queue 7. See the description for qosSwitch8948PortQueue0Length
        to understand the meaning of queue numbers."
    ::= { qosSwitch8948PortEntry 14 }

-- ============================================================================
-- Traffic Class counters table
-- ============================================================================

qosSwitch8948TrafficClassCountersTable OBJECT-TYPE
    SYNTAX      SEQUENCE OF QosSwitch8948TrafficClassCountersEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "Traffic class counters indexed by port, policy and traffic
        class."
    ::= { qosSwitch8948 2 }

qosSwitch8948TrafficClassCountersEntry OBJECT-TYPE
    SYNTAX      QosSwitch8948TrafficClassCountersEntry
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "A traffic class counters entry containing QOS counters for a
        particular port, policy and traffic class."
    INDEX       { qosSwitch8948TCCountersPortIndex,
                  qosSwitch8948TCCountersPolicyIndex,
                  qosSwitch8948TCCountersTrafficClassIndex }
    ::= { qosSwitch8948TrafficClassCountersTable 1 }

QosSwitch8948TrafficClassCountersEntry ::=
    SEQUENCE {
        qosSwitch8948TCCountersPortIndex
            Integer32,
        qosSwitch8948TCCountersPolicyIndex
            Integer32,
        qosSwitch8948TCCountersTrafficClassIndex
            Integer32,
        qosSwitch8948TCCountersAggregateBytes
            Counter32,
        qosSwitch8948TCCountersBwConformanceClass1Bytes
            Counter32,
        qosSwitch8948TCCountersBwConformanceClass2Bytes
            Counter32,
        qosSwitch8948TCCountersBwConformanceClass3Bytes
            Counter32,
        qosSwitch8948TCCountersDroppedBytes
            Counter32
    }

qosSwitch8948TCCountersPortIndex OBJECT-TYPE
    SYNTAX      Integer32 (0..2147483647)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index of the port for this entry in the traffic class
        counter table. This index is the same as the port index in the
        port table and is the same as the port number of the port in
        user commands."
    ::= { qosSwitch8948TrafficClassCountersEntry 1 }

qosSwitch8948TCCountersPolicyIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..256)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index of the policy for this entry in the traffic class
        counter table. Each port can only have one policy assigned at a
        time. Policy index numbers for CLI commands start at 0, while SNMP
        indexes must start at 1. This means that the policy index in this
        MIB variable is 1 more than the index for the same policy as
        entered for CLI commands."
    ::= { qosSwitch8948TrafficClassCountersEntry 2 }

qosSwitch8948TCCountersTrafficClassIndex OBJECT-TYPE
    SYNTAX      Integer32 (1..1024)
    MAX-ACCESS  not-accessible
    STATUS      current
    DESCRIPTION
        "The index of the traffic class for this entry in the traffic
        class counter table. The index is one of the indices defined for
        traffic classes for this port and policy. Traffic class indices
        for CLI commands start at 0, while SNMP indices must start at 1.
        This means that the traffic class index in this MIB variable is 1
        more than the index for the same traffic class as entered for CLI
        commands."
    ::= { qosSwitch8948TrafficClassCountersEntry 3 }

qosSwitch8948TCCountersAggregateBytes OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The total number of bytes classified by this traffic class for
		this policy on this port."
    ::= { qosSwitch8948TrafficClassCountersEntry 4 }

qosSwitch8948TCCountersBwConformanceClass1Bytes OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes classified by this traffic class for this
        policy on this port conforming to bandwidth class 1."
    ::= { qosSwitch8948TrafficClassCountersEntry 5 }

qosSwitch8948TCCountersBwConformanceClass2Bytes OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes classified by this traffic class for this
        policy on this port conforming to bandwidth class 2."
    ::= { qosSwitch8948TrafficClassCountersEntry 6 }

qosSwitch8948TCCountersBwConformanceClass3Bytes OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes classified by this traffic class for this
        policy on this port conforming to bandwidth class 3."
    ::= { qosSwitch8948TrafficClassCountersEntry 7 }

qosSwitch8948TCCountersDroppedBytes OBJECT-TYPE
    SYNTAX      Counter32
    MAX-ACCESS  read-only
    STATUS      current
    DESCRIPTION
        "The number of bytes dropped by this traffic class for this
        policy on this port."
    ::= { qosSwitch8948TrafficClassCountersEntry 8 }

END